Does an EICR have to be satisfactory?

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Electrical safety wording can cause immediate concern. We regularly speak with landlords, managing agents and homeowners who see the word “unsatisfactory” on their Electrical Installation Condition Report and assume they have failed a legal requirement. In practice, the position is more technical and far less dramatic. An EICR is an inspection document. It records the condition of an installation at a specific point in time, highlights safety concerns, and assigns classification codes that determine what action is required.

The real issue is not the label on the front page, but how the findings are handled. Through our experience delivering an Electrical Installation Condition Report (EICR) across domestic and commercial properties, we see how outcomes connect directly to compliance duties, remedial planning, and ongoing maintenance strategy.

What an EICR Is Checking

An EICR assesses the condition of an electrical installation against BS 7671, the UK national standard for electrical installations. It is not a requirement to upgrade every installation to the latest edition in full. Instead, it focuses on safety, deterioration, suitability of protective measures, and risk of electric shock or fire.

During an inspection, we examine consumer units, protective devices, earthing and bonding arrangements, wiring systems, and a representative sample of circuits and accessories. Testing forms part of the process. This includes dead testing, live testing, and verification that disconnection times and protective measures operate within safe limits. The outcome is based on the observations recorded and the classification codes applied to each one.

Early clarity around scope and reporting is essential, which is why we explain our process clearly when arranging an Electrical Installation Condition Report (EICR).

What “Satisfactory” Means in Practice

The overall result of an EICR will be marked either “Satisfactory” or “Unsatisfactory”. This is determined entirely by the classification codes assigned to the observations within the report.

The coding structure is straightforward:

  • C1: Danger present. Risk of injury. Immediate remedial action required.
  • C2: Potentially dangerous. Urgent remedial action required.
  • FI: Further investigation required without delay.
  • C3: Improvement recommended.

If an installation contains any C1, C2 or FI observation, the overall outcome will be “Unsatisfactory”. If only C3 observations are recorded, the report can still be marked “Satisfactory”.

This distinction matters. A property can receive recommendations for improvement and still meet the threshold for a satisfactory report. C3 items highlight areas where modern standards have advanced, but they do not indicate danger.

Does an EICR Have to Be Satisfactory for Legal Compliance?

In England, landlords in the private rented sector must ensure electrical installations are inspected and tested at least every five years and that they meet required safety standards. The official government guidance on Electrical Safety Standards in the Private Rented Sector sets out these duties in detail.

The legislation requires a valid inspection and the completion of any remedial or investigative work identified. It does not state that the initial EICR must be satisfactory. An unsatisfactory report remains a valid inspection document. Compliance depends on carrying out the necessary remedial or further investigative work within the required timeframe.

Where C1, C2 or FI items are identified, landlords must ensure remedial work or investigation is completed within 28 days, or sooner if the report specifies. Written confirmation from a qualified person must then be obtained and supplied to tenants and, if requested, the local authority. Once that process is complete and documented, the landlord has met their obligations.

What Happens After an Unsatisfactory EICR

An unsatisfactory outcome should lead to structured action.

C1 observations indicate immediate danger. In many cases, we make the installation safe at the time of inspection by isolating the affected circuit or carrying out minor corrective work. This is clearly recorded in the report.

C2 observations require urgent remedial action. Examples include inadequate earthing or bonding, absence of appropriate RCD protection in specific circumstances, overheating connections, or damaged accessories. These issues present realistic risk and should be addressed promptly.

FI observations require further investigation before safety can be confirmed. This may arise from unexpected test results, suspected faults, or inaccessible areas that prevent full assessment. Until the investigation is completed, the installation cannot be confirmed as satisfactory.

We explain common triggers and coding decisions in greater detail in our article on what makes an EICR unsatisfactory.

Do You Need a New EICR After Remedial Work?

A full new EICR is not automatically required after completing remedial works.

The regulations require written confirmation from a qualified person that the remedial or investigative work has been carried out and that the electrical safety standards are now met. Depending on the scale of work, this may take the form of:

  • A Minor Electrical Installation Works Certificate
  • An Electrical Installation Certificate
  • A written statement referencing the original EICR observations and confirming they have been rectified

If works are extensive or involve significant alteration, further inspection may be advisable. That decision is based on professional judgement and scope of work rather than a fixed rule.

Owner-Occupiers and Property Sales

For owner-occupiers, there is no universal legal requirement to hold a satisfactory EICR unless linked to tenancy, insurance, or another contractual condition. During property sales, however, buyers and lenders often request an EICR as part of due diligence.

An unsatisfactory report does not invalidate a transaction. It becomes a practical matter of negotiation. The buyer may request remedial works before exchange or adjust the purchase price to reflect the cost of bringing the installation up to standard.

In this context, the value of the EICR lies in transparency. It provides an evidence-based assessment that allows informed decisions to be made.

Commercial and Managed Properties

In commercial environments, EICRs form part of a wider health and safety framework. Those in control of premises must ensure electrical systems are maintained to prevent danger. Inspection frequency may be shorter than five years, depending on risk assessment and usage.

An unsatisfactory report in a commercial setting typically feeds into a defined remedial programme with documented sign-off. Insurers and internal compliance procedures often require evidence of completion within set timescales.

From our perspective, clarity of documentation is as important as the remedial work itself. A well-structured audit trail simplifies future inspections and reduces compliance risk.

Reducing the Risk of Repeat Unsatisfactory Outcomes

Proactive maintenance significantly reduces disruption at the point of inspection. Addressing visible damage, ensuring bonding connections are intact, and reviewing older protective devices before the five-year mark all contribute to smoother outcomes.

Access arrangements also matter. FI codes frequently arise because consumer units, meters or bonding points cannot be accessed fully. Ensuring clear access on inspection day avoids unnecessary follow-up visits.

Selecting a competent inspector ensures consistent coding and defensible reporting. Balanced assessments prevent over-coding while maintaining safety standards.

FAQs

Is an unsatisfactory EICR a failed inspection?

No. It is a valid inspection document that identifies issues requiring urgent action or further investigation before the installation can be confirmed as safe.

Can a property be let with an unsatisfactory EICR?

In the private rented sector, remedial or investigative work must be completed within the required timeframe and confirmed in writing. Once this is done, the landlord meets their legal obligations.

Do C3 items need to be fixed for a satisfactory result?

No. C3 items are recommendations for improvement. They do not prevent the report from being marked satisfactory.

Conclusion

An EICR does not have to be satisfactory at the moment it is issued in order to serve its purpose. The inspection provides a structured assessment of risk. Where C1, C2 or FI observations are present, the focus shifts to timely remedial action and clear documentation.

From our experience, the most effective compliance approach is proactive rather than reactive. Understanding the coding system, planning remedial works promptly, and keeping accurate records creates certainty and reduces disruption at future inspections. A report marked unsatisfactory is not a failure. It is a clear instruction to act.

If you would like support reviewing your report or arranging inspection and remedial works, our team can assist through our contact page.

Disclaimer: The information provided on this website is for general informational and educational purposes only. The content, including all 'how-to' guides and advice should not be a substitute for professional electrical advice. Electrical work can be hazardous and should only be undertaken by qualified professionals. We do not accept any responsibility for any loss, damage, or injury resulting from the use of this information. It is strongly recommended that you consult a certified electrician for personalised advice and to handle any electrical repairs or installations. Always adhere to local building regulations and safety standards.
NAPIT Approved Electrical Logo
BPEC
City & Guilds
Ohme
HyperVolt
EO
My Energi
Lutron
GivEnergy
Loxone
read more
read less